| Dimensions without packaging (H x W x D) [mm(in.)] |
Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 320.0 mm x 210.0 mm (1.72 in. x 12.6 in. x 8.27 in.)
Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 320.0 mm x 217.0 mm (1.72 in. x 12.6 in. x 8.54 in.)
|
| Dimensions with packaging (H x W x D) [mm(in.)] |
90.0 mm x 460.0 mm x 280.0 mm (3.54 in. x 18.11 in. x 11.02 in.) |
| Chassis height [U] |
1 U |
| Chassis material |
Metal |
| Weight without packaging [kg(lb)] |
1.74 kg (3.84 lb) |
| Weight with packaging [kg(lb)] |
2.30 kg (5.07 lb) |
| Typical power consumption [W] |
11.0 W |
| Typical heat dissipation [BTU/hour] |
37.5 BTU/hour |
| Maximum power consumption [W] |
12 W |
| Maximum heat dissipation [BTU/hour] |
40.9 BTU/hour |
| Static power consumption [W] |
3 W |
| MTBF [years] |
78.75 years |
| MTTR [hours] |
2 hours |
| Availability |
> 0.99999 |
| Noise at normal temperature (acoustic power) [dB(A)] |
Noise-free (no fans), < 30 |
| Noise at normal temperature (acoustic pressure) [dB(A)] |
Noise-free (no fans), < 20 |
| Number of card slots |
0 |
| Number of power slots |
0 |
| Number of fans modules |
0 |
| Working mode |
- Standard mode
- Port isolation
- Uplink aggregation
- Flow control disabling
|
| MAC address entry |
8K |
| Redundant power supply |
Not supported |
| Long-term operating temperature [°C(°F)] |
0°C to 40°C (32°F to 104°F) at an altitude of 0-1800 m (0-5906 ft.) |
| Restriction on the operating temperature variation rate [°C(°F)] |
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
| Storage temperature [°C(°F)] |
–40°C to +70°C (–40°F to +158°F) |
| Long-term operating relative humidity [RH] |
5% RH to 95% RH (non-condensing) |
| Long-term operating altitude [m(ft.)] |
0–5000 m (0–16404 ft.) |
| Storage altitude [m(ft.)] |
0-5000 m (0-16404 ft.) |
| Power supply mode |
AC built-in |
| Rated input voltage [V] |
AC input: 100–240 V AC; 50/60 Hz |
| Input voltage range [V] |
AC input: 90 V AC to 264 V AC; 45 Hz to 65 Hz |
| Maximum input current [A] |
1 A |
| Memory |
- |
| Flash memory |
- |
| Console port |
Not supported |
| Eth Management port |
Not supported |
| USB |
Not supported |
| RTC |
Not supported |
| RPS input |
Not supported |
| Service port surge protection [kV] |
Common mode: ±6 kV |
| Power supply surge protection [kV] |
±2 kV in differential mode, ±4 kV in common mode |
| Ingress protection level (dustproof/waterproof) |
IP20 |
| Types of fans |
None |
| Heat dissipation mode |
Natural heat dissipation |
| Airflow direction |
- |
| PoE |
Not supported |
| Certification |
EMC certification
Safety certification
Manufacturing certification
|