| Dimensions without packaging (H x W x D) [mm(in.)] |
Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.54 in.)
Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 446.0 mm (1.72 in. x 17.4 in. x 17.56 in.)
|
| Dimensions with packaging (H x W x D) [mm(in.)] |
185.0 mm x 650.0 mm x 550.0 mm (7.28 in. x 25.59 in. x 21.65 in.) |
| Chassis height [U] |
1 U |
| Chassis material |
Metal |
| Weight without packaging [kg(lb)] |
4.71 kg (10.38 lb) |
| Weight with packaging [kg(lb)] |
6.89 kg (15.19 lb) |
| Typical power consumption [W] |
54.8 W |
| Typical heat dissipation [BTU/hour] |
186.98 BTU/hour |
| Maximum power consumption [W] |
- Without PoE: 77.70 W
- Full PoE load: 517.30 W (PoE: 400 W)
|
| Maximum heat dissipation [BTU/hour] |
- Without PoE: 265.12
- Full PoE load: 1765.08
|
| Static power consumption [W] |
37.1 W |
| MTBF [years] |
54.48 years |
| MTTR [hours] |
2 hours |
| Availability |
> 0.99999 |
| Noise at normal temperature (acoustic power) [dB(A)] |
47.9 dB(A) |
| Noise at normal temperature (acoustic pressure) [dB(A)] |
34.22 dB(A) |
| Number of card slots |
0 |
| Number of power slots |
0 |
| Number of fans modules |
2 |
| Redundant power supply |
Not supported |
| Long-term operating temperature [°C(°F)] |
–5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5905.44 ft.) |
| Restriction on the operating temperature variation rate [°C(°F)] |
When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
Devices cannot start when the temperature is lower than 0°C (32°F).
The operating temperature ranges from –5°C (23°F) to +45°C (113°F) when optical modules with transmission distances greater than or equal to 60 km are used.
|
| Storage temperature [°C(°F)] |
–40°C to +70°C (–40°F to +158°F) |
| Long-term operating relative humidity [RH] |
5% RH to 95% RH (non-condensing) |
| Long-term operating altitude [m(ft.)] |
0–5000 m (0–16404 ft.) |
| Storage altitude [m(ft.)] |
0-5000 m (0-16404 ft.) |
| Power supply mode |
AC built-in |
| Rated input voltage [V] |
- AC input: 100 V AC to 240 V AC, 50/60 Hz
- High-voltage DC input: 240 V DC
|
| Input voltage range [V] |
- AC input: 90 V AC to 290 V AC; 45 Hz to 65 Hz
- High-voltage DC input: 190 V DC to 290 V DC
|
| Maximum input current [A] |
6 A |
| Memory |
2 GB |
| Flash memory |
Physical space: 1 GB |
| Console port |
RJ45 |
| Eth Management port |
Not supported |
| USB |
Supported |
| RTC |
Not supported |
| RPS input |
Not supported |
| Power supply surge protection [kV] |
Differential mode: ±6 kV; common mode: ±6 kV |
| Ingress protection level (dustproof/waterproof) |
IP20 |
| Types of fans |
Built-in |
| Heat dissipation mode |
Air cooling for heat dissipation, intelligent fan speed adjustment |
| Airflow direction |
Air intake from left and front, air exhaustion from right |
| PoE |
Supported |
| Certification |
EMC certification
Safety certification
Manufacturing certification
|