Dimensions without packaging (H x W x D) [mm(in.)] |
Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.)
Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 446.0 mm (1.72 in. x 17.40 in. x 17.56 in.)
|
Dimensions with packaging (H x W x D) [mm(in.)] |
185.0 mm x 650.0 mm x 550.0 mm (7.28 in. x 25.59 in. x 21.65 in.) |
Chassis height [U] |
1 U |
Chassis material |
Metal |
Weight without packaging [kg(lb)] |
5.6 kg (12.35 lb) |
Weight with packaging [kg(lb)] |
7.4 kg (16.31 lb) |
Typical power consumption [W] |
31.6 W |
Typical heat dissipation [BTU/hour] |
107.82 BTU/hour |
Maximum power consumption [W] |
- 48.70 W (with two 80 W AC power modules)
- 85.78 W (with two 1200 W DC power modules)
|
Maximum heat dissipation [BTU/hour] |
- 166.17 (with two 80 W AC power modules)
- 292.69 (with two 1200 W DC power modules)
|
Static power consumption [W] |
14 W |
MTBF [years] |
112.03 years |
MTTR [hours] |
2 hours |
Availability |
> 0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] |
38.1 dB(A) |
Noise at normal temperature (acoustic pressure) [dB(A)] |
26.1 dB(A) |
Number of card slots |
0 |
Number of power slots |
2 |
Number of fans modules |
2 |
Redundant power supply |
1+1
Power modules without fans and power modules with fans cannot be installed in the same chassis.
|
Long-term operating temperature [°C(°F)] |
-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] |
When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
Devices cannot start when the temperature is lower than 0°C (32°F).
|
Storage temperature [°C(°F)] |
–40°C to +70°C (–40°F to +158°F) |
Long-term operating relative humidity [RH] |
5% RH to 95% RH (non-condensing) |
Long-term operating altitude [m(ft.)] |
0–5000 m (0–16404 ft.) |
Storage altitude [m(ft.)] |
0-5000 m (0-16404 ft.) |
Power supply mode |
Pluggable power supply |
Rated input voltage [V] |
- AC input: 100 V AC to 240 V AC; 50/60 Hz
- High-voltage DC input: 240 V DC
- DC input: –48 V DC to –60 V DC
|
Input voltage range [V] |
- AC input: 90 V AC to 290 V AC; 45–65 Hz
- High-voltage DC input: 190 V DC to 290 V DC
- DC input: -38.4 V DC to -72 V DC
|
Maximum input current [A] |
The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules. |
Memory |
2 GB |
Flash memory |
Physical space: 1 GB |
Console port |
RJ45 |
Eth Management port |
Supported |
USB |
Supported |
RTC |
Not supported |
RPS input |
Not supported |
Power supply surge protection [kV] |
- Configured with AC power modules: ±6 kV in differential mode and ±6 kV in common mode
- Configured with DC power modules: ±2 kV in differential mode and ±4 kV in common mode
|
Ingress protection level (dustproof/waterproof) |
IP20 |
Types of fans |
Built-in |
Heat dissipation mode |
Air cooling for heat dissipation, intelligent fan speed adjustment |
Airflow direction |
Air intake from left, front, and right and air exhaust from rear |
PoE |
Not supported |
Certification |
EMC certification
Safety certification